OVERVIEW

With over 20,000 devices deployed globally, the FLIR identiFINDER R400 is the most widely deployed handheld radionuclide identification device (RID) in the world. It is used to detect, locate, measure, and identify radioactive sources and produces rapid visible, audible, and tactile alerts that expedite response measures. The identiFINDER R400 provides operators the ideal balance of size and weight for a wide variety of monitoring scenarios including all-purpose surveying, emergency response, and environmental monitoring.

CALL FOR QUOTE PLEASE 

Description

ALL-PURPOSE, FIELD- PROVEN RADIOLOGICAL SURVEYING

  • Over 20,000 deployed globally for tough, tried- and-true performance
  • NaI or LaBr detectors provide custom solutions for sensitivity and resolution
  • Available in gamma only or gamma and neutron models
  • Underwater model able to withstand submersion up to 10 meters

FAST, RELIABLE IDENTIFICATION AND DETECTION

  • Rugged and mission-ready for fast front-line detection and response
  • Quickly and efficiently detect, locate, measure, and identify sources
  • Back-up gamma detector provides detection capability, even in high dose rate environments
  • Identifies ANSI N42.34 library
  • High resolution, low false alarms

RAPID ALERTS AND COMMUNICATIONS FOR EXPEDITED DECISION- MAKING

  • Easily transfer important tactical information
  • Fast two-minute startup
  • On-board GPS, webserver, and Bluetooth capabilities
  • Common operating interface reduces training burden
  • Large, color display eases data interpretation
SYSTEM OVERVIEW
Data Storage
2GB internal memory; up to 600,000 spectra
Training Requirements
< 10 mins for operator; 1 day for advanced user
ENVIRONMENTAL
Operating Humidity
10 to 80%;
Operating Temperature
-4 to 122 °F(-20 to 50 °C)
Storage Temperature
14 to 95 °F(-10 to 35 °C)
OTHER
Global Positionsing System [GPS] [removable]
12-channel SiRF III receiver
PHYSICAL FEATURES
Dimensions (L x W x H)
≤3.7 x 10.6 x 3.2 in (9.4 x 26.9 x 8.1 cm) -with battery
Weight
≤3.2 lbs(≤1.5 kg)
POWER
Battery Specs
Either rechargeable NiMH or 4x AA pack(supplied); ≥8h operational battery life; recharge ≤4h when using AC; recharge >4h when using USB
Cold Start Time
< 2 mins from cold start
Input Voltage
100-240 VAC (wall and car adapters and USB cable supplied)
SAMPLING & ANALYSIS
Nuclide Identification
According to ANSI N42.34
Sample Introduction
Absorption of EM gamma or neutron emissions
Sampling & Analysis
From a few seconds to minutes
Threats
Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
SYSTEM INTERFACE
Software
On-board webserver software
TECHNOLOGY
Dose Range
0 nSv – 1 Sv (0 nrem – 100 rem)
Dose Rate & Accuracy (Cs-137)
0 nSv/h – 10.00mSv/h (0 nrem/h – 1.0 rem/h); ±30 %
Energy Range [Gamma]
20 keV – 3 MeV
Gamma [High Dose Rate]
Geiger-Mller
Gamma LaBr3
1.2 x 1.2 in (30 x 30 mm)
Gamma Spectrum
1024 channels; 3 MeV
Geiger-Muller Dose Rate Range
100 µSv/h – 10mSv/h (10mrem/h – 1.0 rem/h)

Neutron Sensitivity

            2.6 cps/nv; ±20 %

Overload Dose Rate Range

10 mSv/h – 1 Sv/h (1.0 rem/h – 100 rem/h)
Scintillator Dose Rate Range
0 nSv/h – 500 µSv/h (0 nrem/h – 50mrem/h)
Service Interval
5 year factorymaintenance
Stabilization
LED
Typical Resolution
4.5 % FWHM at 662 keV